Proline Promass F 200 - Coriolis Flowmeter

 

 

Promass F has a long standing reputation as a highly accurate device under varying process conditions.
It is suited for broadest range of applications. Promass F 200 offers in addition genuine,
industry-compliant two-wire technology. This enables the device to be seamlessly integrated
into existing infrastructures and control systems. Additional advantages are high operational
safety in hazardous areas thanks to an intrinsically safe design (Ex ia), and a familiar installation procedure.

Benefits

 

  • Highest process safety – immune to fluctuating and harsh environments

  • Fewer process measuring points – multivariable measurement (flow, density, temperature)

  • Space-saving installation – no in/outlet run needs

  • Convenient device wiring – separate connection compartment

  • Safe operation – no need to open the device due to display with touch control, background lighting

  • Integrated verification – Heartbeat Technology

 

Field of application

 

  • Measuring principle operates independently of physical fluid properties such as viscosity or density

  • Highest measurement performance for liquids and gases under varying, demanding process conditions.

Device properties

  • Mass flow: measured error ±0,1 %

  • Rated secondary containment up to 40 bar (580 psi)

  • Nominal diameter: DN 8 to 80 (3/8 to 3")

  • Loop-powered technology

  • Robust two-chamber housing

  • Plant safety: worldwide approvals (SIL, Haz. area)

 

Features and specifications

Gas

 

Measuring Principle Coriolis
Product headline The genuine loop‐powered robust flowmeter for demanding applications. Highest measurement performance for liquids and gases under varying, demanding process conditions.
Sensor features Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Mass flow: measured error ±0.1 %. Medium temperature up to 205 °C (401 °F).
Transmitter features Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology. Loop‐powered technology. Robust dual- compartment housing.
Nominal diameter range DN 8 to 80 (⅜ to 3")
Wetted materials Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density
Max. measured error Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 70 000 kg/h (0 to 2570 lb/min)
Max. process pressure PN 100, Class 600, 63K
Medium temperature range Standard: –50 to +150 °C (–58 to +302 °F)
Option: –50 to +205 °C (–58 to +401 °F)
Ambient temperature range –40 to +60 °C (–40 to +140 °F)
Sensor housing material 1.4301/1.4307 (304L), corrosion resistant
Transmitter housing material AlSi10Mg, coated, 1.4404 (316L)
Degree of protection IP66/67, type 4X enclosure
Display/Operation 4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available
Outputs 4‐20 mA HART (passive)
4‐20 mA (passive)
Pulse/frequency/switch output (passive)
Inputs None
Digital communication HART, PROFIBUS PA, FOUNDATION Fieldbus
Power supply DC 18 to 35 V (4‐20 mA HART with/without pulse/frequency/switch)
DC 18 to 30 V (20 mA HART, 4‐20 mA)
DC 9 to 32 V (PROFIBUS PA)
Hazardous area approvals ATEX, IECEx, cCSAus
Other approvals and certificates 3.1 material, calibration performed on accredited calibrationfacilities (acc. to ISO/IEC 17025), NAMUR, SIL
Heartbeat Technolgy complies with the requirements for traceable verification according to ISO 9001:2008 - Section 7.6 a (TÜV attestation)
PED, CRN, AD 2000
3-A, EHEDG
NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK

Liquids

Measuring Principle Coriolis
Product headline Robust flowmeter with genuine loop‐powered technology. Highest measurement performance for liquids and gases in a wide range of applications.
Sensor features Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Mass flow: measured error ±0.1 %. Medium temperature up to +205 °C (+401°F).
Transmitter features Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology. Loop‐powered Technology. Robust dual‐compartment housing.
Nominal diameter range DN 8 to 80 (⅜ to 3")
Wetted materials Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density
Max. measured error Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 70 000 kg/h (0 to 2570 lb/min)
Max. process pressure PN 100, Class 600, 63K
Medium temperature range Standard: –50 to +150 °C (–58 to +302 °F)
Option: –50 to +205 °C (–58 to +401 °F)
Ambient temperature range –40 to +60 °C (–40 to +140 °F)
Sensor housing material 1.4301/1.4307 (304L), corrosion resistant
Transmitter housing material AlSi10Mg, coated, 1.4404 (316L)
Degree of protection IP66/67, type 4X enclosure
Display/Operation 4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available
Outputs 4‐20 mA HART (passive)
4‐20 mA (passive)
Pulse/frequency/switch output (passive)
Inputs None
Digital communication HART, PROFIBUS PA, FOUNDATION Fieldbus
Power supply DC 18 to 35 V (4‐20 mA HART with/without pulse/frequency/switch)
DC 18 to 30 V (20 mA HART, 4‐20 mA)
DC 9 to 32 V (PROFIBUS PA)
Hazardous area approvals ATEX, IECEx, cCSAus, INMETRO
Other approvals and certificates 3.1 material, calibration performed on accredited calibrationfacilities (acc. to ISO/IEC 17025), NAMUR
Heartbeat Technology complies with the requirements for traceable verification according to ISO 9001:2008 – Section 7.6 a (TÜV Attestation)
SIL
PED, CRN, AD 2000
3-A, EHEDG,
NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK