Liquiphant FTL20H - Vibronic Point level detection

Liquiphant FTL20H is a point level switch with compact hygiene design for use in storage tanks,
agitators and pipes which have to meet particularly high hygiene standards internally and externally.
FTL20H can be used as an overfill prevention or as a pump dry-run protector.
The measurement is unaffected of viscosity, build-up, turbulences, flows, air bubbles or temperature
changes during cleaning. Functional check in installed state from the outside possible. EHEDG approval available.
 

Benefits

  • Designed for hygienic applications especially in the food industry

  • CIP and SIP cleanability ensured

  • Up to protection class IP69k

  • Hygienic process connections and approvals

  • Measurement is unaffected by conductivity, build-up, turbulence, flows or air bubbles

  • Simple and fast commissioning. No calibration required

  • No mechanically moved parts, free of maintenance

 

Field of application
 

Compact point level switch for liquids meets the high hygiene standards in the food industry.

  •  Process connections: Threads or process connections for hygiene requirements (Tri-Clamp, dairy coupling, flush mount solutions)

  • Temperature: -40 to +150°C (-40 to +302°F)

  • Pressure: -1 to +40bar (-14.5 to +580psi)

  • Overfill prevention WHG, hygienic certificates

 

 

Features and specifications

 
Measuring Principle Vibration Liquids
Characteristic / Application most compact
hygiene housing and process connections
CIP / SIP 
Switch point 38mm
EHEDG approvals
 
Supply / Communication 19 ... 253V AC
10 ... 35V DC-PNP
ASI-Bus
Ambient temperature -40 °C ... 70 °C
(-40 °F ... 158 °F)
-25 °C ... 70 °C - ASi
(-13 °F ... 158 °F - ASi)
Process temperature -40 °C ... 150 °C
(-40 °F ... 302 °F)
Process pressure absolute / max. overpressure limit Vacuum ... 40 bar
(Vacuum ... 580 psi)
Min. density of medium 0,7g/cm3
(0,5g/cm3 optional)
Main wetted parts 316L
Process connection G1/2A, G3/4A, G1A, NPT1/2", NPT3/4", R1/2", R3/4"
Process connection hygienic Tri-Clamp ISO2852
Dairy coupling
Flush mount solutions
Sensor length 64mm (2.52")
Output AC, DC-PNP, ASi
Certificates / Approvals WHG/ Overfill prevention
EHEDG
GL Marine
Successor Product phase out planned,
Successor FTL33