Omnigrad T TST41N - Modular RTD thermometer

The thermometer is mainly used in the chemical industry but also finds its use in other branches.
The device with head transmitter is a complete unit ready for use with enhanced measurement
accuracy and reliability compared to directly wired sensors. A variety of process connections,
dimensions and materials offer flexible application possibilities.

 

Benefits

  • High degree of flexibility thanks to modular design with standard
    terminal heads as per DIN EN 50446 and customer-specific immersion lengths

  • High degree of insert compatibility and design as per DIN 43772

  • Fast response time with reduced/tapered tip form

  • Head transmitter with easy selection: Analog output 4 to 20 mA, HART®,
    PROFIBUS® PA or FOUNDATION Fieldbus™

 

Field of application

The TST41N RTD thermometer is a general purpose assembly suitable for liquids and gases.

 

Features and specifications

 
Measuring Principle Resistance Temperature Detector
Characteristic / Application metric style
modular temperature assembly
fast response time (reduced/tapered tip)
threaded process connection
without neck
Terminal head TA20A - aluminium - cover with screws
TA20D - aluminium - hinged cover high
TA30A - E+H, aluminium - cover low - w. or w/o. display
TA30D - E+H, aluminium - cover high
Thermowell / protection tube without (not intended to use with thermowell)
Insert / probe mineral insulated (MI), flexible
Outer diameter protection tube 6,0 mm (0,24'') 
9,0 mm (0,35'') 
Max. immersion length on request up to 10.000,00 mm (393,70'')
Material protection tube/thermowell 1.4404 (316L)  
Process connection male thread:
G1/2"
G3/4"
G1"
NPT1/2"
NPT3/4"
NPT1"
M20x1.5
Tip shape reduced 
Surface roughness Ra 0,8 μm (31,5 μin.) 
Operating temperature range PT 100:
-50 °C ... 600 °C
(-58 °F ...1.112 °F) 
Max. process pressure (static) at 20 °C: 20 bar (290 psi) 
Accuracy class A acc. to IEC 60751
1/3 DIN class B acc. to IEC 60751
Response time depending on configuration
t50 = 3 s
t90 = 6 s
Integration head transmitter yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)