Omnigrad T TST41N - Modular RTD thermometer
The thermometer is mainly used in the chemical industry but also finds its use in other branches.
The device with head transmitter is a complete unit ready for use with enhanced measurement
accuracy and reliability compared to directly wired sensors. A variety of process connections,
dimensions and materials offer flexible application possibilities.

Benefits
-
High degree of flexibility thanks to modular design with standard
terminal heads as per DIN EN 50446 and customer-specific immersion lengths -
High degree of insert compatibility and design as per DIN 43772
-
Fast response time with reduced/tapered tip form
-
Head transmitter with easy selection: Analog output 4 to 20 mA, HART®,
PROFIBUS® PA or FOUNDATION Fieldbus™
Field of application
The TST41N RTD thermometer is a general purpose assembly suitable for liquids and gases.
Features and specifications
| Measuring Principle | Resistance Temperature Detector | |
| Characteristic / Application |
metric style modular temperature assembly fast response time (reduced/tapered tip) threaded process connection without neck |
|
| Terminal head |
TA20A - aluminium - cover with screws TA20D - aluminium - hinged cover high TA30A - E+H, aluminium - cover low - w. or w/o. display TA30D - E+H, aluminium - cover high |
|
| Thermowell / protection tube | without (not intended to use with thermowell) | |
| Insert / probe | mineral insulated (MI), flexible | |
| Outer diameter protection tube |
6,0 mm (0,24'') 9,0 mm (0,35'') |
|
| Max. immersion length on request | up to 10.000,00 mm (393,70'') | |
| Material protection tube/thermowell | 1.4404 (316L) | |
| Process connection |
male thread: G1/2" G3/4" G1" NPT1/2" NPT3/4" NPT1" M20x1.5 |
|
| Tip shape | reduced | |
| Surface roughness Ra | 0,8 μm (31,5 μin.) | |
| Operating temperature range |
PT 100: -50 °C ... 600 °C (-58 °F ...1.112 °F) |
|
| Max. process pressure (static) | at 20 °C: 20 bar (290 psi) | |
| Accuracy |
class A acc. to IEC 60751 1/3 DIN class B acc. to IEC 60751 |
|
| Response time |
depending on configuration t50 = 3 s t90 = 6 s |
|
| Integration head transmitter | yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS) | |