Micropilot FMR53 - Radar Measurement Time-of-Flight

 

 

 

 
  • Micropilot FMR53 aluminum housing

     

  •  

     

    spaceplay / pause

     

    qunload | stop

     

    ffullscreen

    shift + slower / faster (latest Chrome and Safari)

    volume

     

    mmute

    seek

     

     . seek to previous

    126 seek to 10%, 20%, …60%

     

     

    Time-of-Flight measuring principle

     

  •  

     

    spaceplay / pause

     

    qunload | stop

     

    ffullscreen

    shift + slower / faster (latest Chrome and Safari)

    volume

     

    mmute

    seek

     

     . seek to previous

    126 seek to 10%, 20%, …60%

     

     

    Commissioning movie for Micropilot FMR5x free space radar and Levelflex FMP5x guided radar

     

  •  

     

    spaceplay / pause

     

    qunload | stop

     

    ffullscreen

    shift + slower / faster (latest Chrome and Safari)

    volume

     

    mmute

    seek

     

     . seek to previous

    126 seek to 10%, 20%, …60%

     

Micropilot FMR53 for simple level measurement applications in liquids. With its slim rod antenna, FMR53 free space radar is particularly suited for small process connections. The PTFE coating of the rod antenna and flange plating guarantee resistance also in aggressive media. The Micropilot FMR53 is used for continuous, non-contact level measurement of liquids, pastes and slurries. The measurement is not affected by changing media, temperature changes, gas blankets or vapors.

 

Benefits

  • Reliable non-contact measurement even for changing product and process conditions

  • HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics

  • Highest reliability even in the presence of obstructions in the vessel due to new Multi-Echo Tracking evaluation

  • Hardware and software developed according to IEC 61508 up to SIL3 (in homogeneous redundancy)

  • Seamless integration into control or asset management systems

  • Intuitive, menu-guided operation concept (on-site or via the control system)

  • World's easiest proof test concept for SIL and WHG saves time and cost

 

 

Field of application

Especially suited for small process connections, PTFE sensors usable in chemically aggressive media.

  • Process connections: Thread or flange

  • Temperature: -40 to +150°C (–40 to +302°F)

  • Pressure range: -1 to +40bar (–14.5 to +580psi)

  • Maximum measuring range: 20m (66ft)

  • Accuracy: ±6mm

  • C-band: 6GHz

  • International explosion protection certificates, 5-point linearity protocol, WHG overfill prevention, SIL

 

 

Features and specifications

Measuring Principle Level radar
Characteristic / Application For common non-contact continuous level measurement in liquids,
especially suited for small process connections and for chemically aggressive media;
Rod antenna with PTFE coating
Supply / Communication 2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
4-wire (HART)
 
Frequency C-band (~6 GHz)
Accuracy +/- 6 mm (0.24 in)
Ambient temperature -40...+80 °C
(-40...+176 °F)
Process temperature -40...+150 °C
(-40...+302 °F)
Process pressure absolute / max. overpressure limit Vacuum...40 bar
(Vacuum...580 psi)
Main wetted parts PTFE, PVDF
Process connection Thread:
MNPT 1 1/2, R 1 1/2 
Flange:
DN50...DN150,
ASME 2"...6",
JIS 10K 
Max. measurement distance 20 m (65 ft)
Output 4...20 mA HART 
PROFIBUS PA
FOUNDATION Fieldbus
 
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, NEPSI, INMETRO, KC
Overfill prevention WHG
SIL
EN 10204-3.1
 
Options Display,
Customized parameterization
Gas-tight feed through
PWIS free 
Specialities SIL 2 according to IEC 61508,
Safety and reliability with Multi-Echo Tracking,
HistoROM
Application limits Maximum measuring range is dependent on the tank form and/or application

Nozzle height >250 mm:
FMR51, FMR52, FMR54
Low DK:
FMR51, FMR52, FMR54