Vibronic point level detection- Soliphant FTM50

 

Universal point level switch for fine-grained bulk solids also for explosion-hazardous areas

Soliphant M is a robust point level switch for use in silos containing fine-grained or powdery solids
even with a low bulk density. Suitable for a wide range of applications with international certificates
for use in dust or gas incendive hazardous areas. Available with polished fork and stainless steel
housing with Tri-Clamp or with aluminum housing and coated fork. Maintenance-free device for use
in typical applications like: cereals, flour, cocoa, sugar, animal feed, dye powder, chalk
 

Benefits

  • SIL2 in accordance with IEC 61508

  • No mechanically moving parts: no wear, long operating life

  • Insensitive to external vibrations and build-up: maintenance-free operation, independent of bulk solids

  • Various electronic inserts: e.g. NAMUR, relay, thyristor and PFM-signal outputs for optimum alignment with the plant control system

  • Build-up and abrasion display selectable Density setting and switching delay selectable

  • Choice of coated or polished sensor

  • Market leader in the area of level detection of bulk solids with practical experience since 1967

Field of application

Point level switch for fine grained solids and powder.

  • Process connections: threads, flanges and hygienic connection (Tri-Clamp)

  • Temperature: -50 to +280°C (-60 to +540°F)

  • Pressure: -1 to +25bar (-14.5 to +360psi)

  • Sensor length: 145mm, 200mm

  • Sensor material: 316L (3,2µm, 0,8µm, PTFE coated, ETFE coated)

  • International explosion protection certificates

Technical information

Point Level / Solids

Measuring Principle Vibration Solids
Characteristic / Application Point level switch for fine grained solids and powder
Fork sensor
Universal
No calibration required
Not affected by build up or external vibration
Robust
Switch value visible from outside
Compact
Supply / Communication 10-55V DC PNP 3-wire
19-253V AC 2-wire 
19...253V AC / 19V...55V DC 2 relay contact
8/16mA
NAMUR
PFM
 
Ambient temperature -50°C ... 70°C
(-60°F ... 160 °F)
Process temperature -50°C ... 280°C
(-60°F ... 540°F)
Process pressure absolute / max. overpressure limit Vacuum ... 25 bar
(Vacuum ... 360 psi)
Min. density of medium 10 g/l (8 g/l on request)
Main wetted parts selectible:
316L 3,2um
316L 0,8um
316L PTFE coated (to avoid build-up)
316L ETFE coated (to avoid corrosion)
 
Process connection Thread
R 1 1/2" 
1 1/4" NPT
1 1/2" NPT
EN Flange DN50...DN100
ASME Flange 2"...4"
JIS Flange 50A...100A
 
Process connection hygienic Tri-Clamp ISO2852
 
Sensor length Standard: 200mm (8") 
Short: 145mm (5.7")
Output DC PNP 2-wire
AC Thyristor
DPDT relay
8/16mA
NAMUR
PFM
 
Certificates / Approvals ATEX, FM, CSA, IECEx, TIIS, NEPSI, INMETRO
SIL
 
Options Glass cover
Temperature spacer
EN10204-3.1
 
Specialities Build-up and corrosion detection 
Remote version
3 temperature versions available
SIL 2
Application limits Grain size > 10mm (0.4")
Components PFM: FTL325P, FTL375P
NAMUR: FTL325N, FTL375N