Prosonic FMU30 - Ultrasonic Measurement Time-of-Flight
The range of applications extends from monitoring levels in sewage treatment
plants and process water tanks to applications for loading, storage and buffer tanks.
FMU30 ultrasonic sensor offers proven software algorithms and all warning and
alarm messages are shown on the four-line plain text display and guarantee fast
remedy of problems. The envelope curve can also be shown on the display.
As the analysis results are displayed directly on-site, this ensures quick and
accurate error diagnostics.
Benefits
-
Quick and simple commissioning via menu-guided onsite operation with four-line plain text display, 7 languages selectable
-
Envelope curves on the on-site display for simple diagnosis
-
Linearization function (up to 32 points) for conversion of the measured value into any unit of length, volume or flow rate
-
Non-contact measurement method minimizes service requirements
-
Installation possible from thread G 1½ or 1½ NPT upwards
-
Integrated temperature sensor for automatic correction of the temperature dependent sound velocity
Field of application
Two-wire instrument for continuous non-contact level and flow measurement.
-
Process connection: Thread
-
Temperature: -20 to +60°C (-4 to +140°F)
-
Pressure: +0.7 to +3bar (+10 to +44psi)
-
Maximum measuring distance:
Sensor 1½" for liquids 5m (16ft) and for bulk solids 2m (6.6ft),
Sensor 2" for liquids 8m (26ft)and for bulk solids 3.5m (11ft) -
Blocking distance:
Sensor 1½" 0.25m (0.8ft),
Sensor 2" 0.35m (1.15ft) -
International explosion protection certificates
Features and specifications
Continuous / Liquids
Measuring Principle | Ultrasonic | |
Characteristic / Application | Compact ultrasonic transmitter | |
Supply / Communication | 2-wire | |
Accuracy | +/- 3 mm or +/- 0,2 % of set measuring range | |
Ambient temperature |
-20 °C ... 60 °C (-4 °F ... 140 °F) |
|
Process temperature |
-20 °C ... 60 °C (- 4°F ... 140 °F) |
|
Process pressure absolute / max. overpressure limit |
0.7 bar ... 3 bar abs (10 psi ... 44 psi) |
|
Main wetted parts | PP/EPDM | |
Process connection |
G / NPT 1 1/2" G / NPT 2" |
|
Blocking distance |
1 1/2" :0.25 m (0.8 ft) 2" :0.35 m (1.15 ft) |
|
Max. measurement distance |
Sensor 1-1/5": 5m (16 ft) Sensor 2" : 8m (26ft) |
|
Output | 4 ... 20 mA | |
Certificates / Approvals | ATEX, CSA C/US, IEC, NEPSI | |
Options |
Accessory Enclosed: UNI flange 2" ... 4" |
|
Application limits |
For higher resistance: FMU41/42/FDU9x Foam / high turbulence possible: FMU42/FDU91 Fast filling and discharging rate: FMU90 + FDU9x Level limit detection: FMU90 + FDU9x |
Continuous / Solids
Measuring Principle | Ultrasonic | |
Characteristic / Application | Compact ultrasonic transmitter | |
Supply / Communication | 2-wire | |
Accuracy | +/- 3 mm or +/- 0.2 % of set measuring range | |
Ambient temperature |
-20 °C ... 60 °C (-4 °F ... 140 °F) |
|
Process temperature |
-20 °C ... 60 °C (-4 °F ... 140 °F) |
|
Process pressure absolute / max. overpressure limit |
0.7 bar ... 3 bar abs (10 psi ... 44 psi) |
|
Main wetted parts | PP/EPDM | |
Process connection |
G / NPT 1 1/2" G / NPT 2" |
|
Blocking distance |
Sensor 1 1/2": 0.25m Sensor 2" : 0.35m |
|
Max. measurement distance |
Sensor 1-1/2": 2m(6.6ft) Sensor 2" : 3.5m (11ft) |
|
Output | 4...20mA | |
Certificates / Approvals | ATEX, CSA C/US, IEC Ex, NEPSI | |
Options |
Accessory Enclosed: UNI flange 2" ... 4" |
|
Application limits | Take notice of range diagram |